BRAND | Vaisala |
Product | GM70 B4A1E1A2B |
Description | Portable CO2 meter |
Internal code | IMP4587659 |
Technical specification | The portable Vaisala CARBOCAP® carbon dioxide meter GM70 is on accuracy over a large measuring range. This model is with various configuration options that are suitable for demanding Sample measurements in HVAC applications (e.g. room and channel measurements in laboratories) as well as for applications in incubators, greenhouses, the food and Beverage production and animal husbandry are suitable. The GM70 can be used for field testing or as Single-point calibration reference for stationary Vaisala transducers like ours GMW90 series devices used will The one included in this meter MI70 display also supports Using other portable probes by Vaisala for dew point, relative humidity and temperature as well as oil moisture. This makes it a versatile investment that different multi-parameter applications are used can. Two probes can be used simultaneously connected to an MI70 display device will be. With the MI70 Link Windows® software (for download on the Vaisala website available) and the USB Connection cables can be logged and real-time measurement data from GM70 can be transferred to a PC. The meter can measure up to 2700 Log real-time data points. Note: If you already have a meter the Vaisala MI70 series (e.g. HM70) , you only need the probe or pump of the GM70 and can they be combined with the existing MI70 Use display device (select in in this case, there is no display device). Please contact Questions for the Vaisala sales team. COO: FI Rechargeable display device with euro power supply Windows software MI70link with USB cable to M12/4 The MI70 link software allows you to monitor measurement readings and Transfer data directly with a PC (Microsoft Windows® required) when a DM70, HM70, MM70 or GM70 (which all include the MI70 indicator) Hand-held meter is connected with the supplied cable. The cable Connects to a PC via a standard type A USB port. Cable length 1.5 m (5 ft). Software and USB driver for Microsoft Windows® delivered on a CD-ROM. Probe with handle for in-situ measurements CO2 measuring range: 5000 ppm Sampling cell/test adapter The field checking adaptor is a Compact plastic chamber that Attaches gas tight around the sensor head of the carbon dioxide sample. It can be used to feed in reference gas when field checking the probe or as a chamber for a pump aspirated sampling system. Instructions for use is included. Compatible with GMP221 and GMP222 probes, which are used in GMT220 series, GMM220 series and GM70 series instruments Weatherproof carrying case Instruction manual GM70 CO2 sample Low Concentrate Varnished & encapsulated |
Discover the superior quality and performance of the Vaisala GM70 B4A1E1A2B with Impexron GMBH in Singapore . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The GM70 B4A1E1A2B is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of GM70 B4A1E1A2B :
At Impexron GMBH , we offer the GM70 B4A1E1A2B at competitive prices and with the fastest delivery times across Singapore . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the GM70 B4A1E1A2B ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Vaisala products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Temperature transmitter
Handheld Moisture and Temperature Meter
MMT 330 2B0F111CPQL113C32EABBB1
MMT330 2B0F111CPQL113C32EABBB1 Oil Moisture And Temperature transmitter Code 2 2 EA Probe (2m assembly) + 180C 2 EA aw + T + 2 ppm EA 0 graphical LCD with Backlight 2 EA Isolating transformer incl. Galvanic separation 2 EA Analog output (CH1 & CH2) 4 ... 20 mA 2 EA 0 Channel 1 T (the area below) EA 2 Aw channel 2 0 ... 1 2 EA Channel 3 ppm 0..100 2 EA Temperature range 0 ... + 100 ° C for 2 EA Metric units 2 EA Relay Module 2 EA 3. Analog Output 2 EA Connectors M12 8-pole with 5 m electric wire 2 EA Rain Cover 2 EA Humidity Sensor HUMICAP180L2 Chem. Resistant 2 EA Stainless steel filter, Lochdurchm. 2mm HF 2 EA Manual MMT330, English 2 EA Interface cable for PC 2 EA Advanced Temperature range calibration 2 EA
MMT330 7S0E101CPAE100A02DABAA1
Moisture in Oil And Temperature Transmitter with Remote Probes MMT337 Probe (2m assembly) + 180C aw + T graphical LCD with Backlight Power supply standard (24 VDC) Analog output Output 4 ... 20 mA Channel 1 T (the area below) Aw channel 2 0 ... 1 Temperature range -40 ... + 180 ° C metric units Cable gland M20 x 1,5 Humidity Sensor HUMICAP180L2 Chem. Resistant stainless steel filter Manual MMT330, English
MMT338 Moisture and Temperature Transmitter for Lubrication and Hydraulic Oils
MMT338 Moisture and Temperature Transmitter for Transformer Oils
flume traffic
NSN:5998-01-467-7811 ( MPU13, 014677811, 5998014677811 )
CIRCUIT CARD ASSEMBLY
Pressure sensor PMT 16 C System : Draft Gauging System Level Datic 100S System Maker - SF Controls
PMT16C (OBSOLETE NO REPLACEMENT)
* Y1130051 * Series numbers
digital barometer
Digital Barometer Model : PTB330 Series
PTU300 13801B1BCAF1A0A1FAE0B4A (PTU301)
(Pressure, Humidity andTemperature Transmitter PTU301 Baro-1 Module ClassA 500-1100 hPa,2pcs BARO-1 0.25m Probe Cable Graphic display with keypad Galvanic Isolation Module Analog Output (CH1,CH2) Output 4...20mA Channel 1 RH (0...100%RH) Channel 2 T (Range See Below) Temperature Range -20...+60C PTU200 Output Format Standard Metric Units Sealed Cable Gland M20x1.5 Pressure Connector M5 (10-32) Wall Mounting Kit with Probe Holder Humicap180R Sensor Stainless Steel Filter HM47453 User´s Guide PTU300 Software Interface Kit with USB-RJ45 Cable)
PTU300 T1H01A1CCPB1A0A1A0A0B0A
(Pressure, humidity and Temperature Transmitter PTU30T Class A / 1 pressure sensor Pressure range: 500 ... 1100 hP 2 m cable, PTU30T graphical LCD with Backlight Power supply standard (24 VDC) Analog output Output 4 ... 20mA Channel 1 T (the area below) Channel 2 T (the area below) P channel 3 (the entire pressure range) Analog Output Modules T-compensated Temperature range -40 ... + 60C Signal format standard metric units Cable gland M20 x 1,5 Hose for 1/8 "hose Manual PTU300)
PTU300 T1H10A1CCPB1A0A1A0A0B0A
(Pressure, humidity and Temperature Transmitter PTU30T Class A / 1 pressure sensor Pressure range: 500 ... 1100 hP 2 m cable, PTU30T Temp probe to 2 m cable Housing without display Power supply standard (24 VDC) Analog output Output 4 ... 20mA Channel 1 T (the area below) Channel 2 T (the area below) P channel 3 (the entire pressure range) Analog Output Modules T-compensated Temperature range -40 ... + 60C Signal format standard metric units Cable gland M20 x 1,5 Hose for 1/8 "hose Manual PTU300)
Pressure, Humidity and Temperature Transmitter
PTU300 12A01C1BCPF1A0A1BAB0B0A
(Pressure, humidity andMeasured temperature transmitter)
PTU300 13801A1BCAF1A0A1FAE0B4A (PTU301)
(Pressure, Humidity andTemperature Transmitter PTU301 Baro-1 Module ClassA 500-1100 hPa,2pcs BARO-1 0.25m Probe Cable Sealed Cable Gland M12x1,5 Graphic display with keypad Standard (24 VDC) Analog Output (CH1,CH2) Output 4...20mA Channel 1 RH (0...100%RH) Channel 2 T (Range See Below) Temperature Range -20...+60C PTU200 Output Format Standard Metric Units Sealed Cable Gland M20x1.5 Pressure Connector M5 (10-32) Wall Mounting Kit with Probe Holder Humicap180R Sensor Stainless Steel Filter HM47453 User´s Guide PTU300 Software Interface Kit with USB-RJ45 Cable)
PTU300 T1H00A1CCPB1A0A1A0A0B0A
(Pressure, humidity and Temperature Transmitter PTU30T Class A / 1 pressure sensor Pressure range: 500 ... 1100 hP 2 m cable, PTU30T Housing without display Power supply standard (24 VDC) Analog output Output 4 ... 20mA Channel 1 T (the area below) Channel 2 T (the area below) P channel 3 (the entire pressure range) Analog Output Modules T-compensated Temperature range -40 ... + 60C Signal format standard metric units Cable gland M20 x 1,5 Hose for 1/8 "hose Manual PTU300)
PTU300 T1H11A1CCPB1A0A1A0A0B0A
(Pressure, humidity and Temperature Transmitter PTU30T Class A / 1 pressure sensor Pressure range: 500 ... 1100 hP 2 m cable, PTU30T Temp probe to 2 m cable graphical LCD with Backlight Power supply standard (24 VDC) Analog output Output 4 ... 20mA Channel 1 T (the area below) Channel 2 T (the area below) P channel 3 (the entire pressure range) Analog Output Modules T-compensated Temperature range -40 ... + 60C Signal format standard metric units Cable gland M20 x 1,5 Hose for 1/8 "hose Manual PTU300)
Visibility sensor